WIRE GAUGE
|
AMPS |
14 |
12 |
10 |
8 |
6 |
4 |
2 |
1 |
0 |
00 |
000 |
0000 |
1 |
213 |
338 |
537 |
854 |
1359 |
2160 |
3434 |
4332 |
5460 |
6887 |
8684 |
10951 |
2
|
106 |
169 |
269 |
427 |
679 |
1080 |
1717 |
2166 |
2730 |
3444 |
4342 |
5475 |
4 |
53 |
85 |
134 |
214 |
340 |
540 |
859 |
1083 |
1365 |
1722 |
2171 |
2738 |
6 |
35 |
56 |
90 |
142 |
226 |
360 |
572 |
722 |
910 |
1148 |
1447 |
1825 |
8 |
27 |
42 |
67 |
107 |
170 |
270 |
429 |
542 |
682 |
861 |
1086 |
1369 |
10 |
21 |
34 |
54 |
85 |
136 |
216 |
343 |
433 |
546 |
689 |
868 |
1095 |
15
|
14 |
23 |
36 |
57 |
91 |
144 |
229 |
289 |
364 |
459 |
579 |
730 |
20 |
— |
17 |
27 |
43 |
68 |
108 |
172 |
217 |
273 |
344 |
434 |
548 |
25 |
— |
— |
21 |
34 |
54 |
86 |
137 |
173 |
218 |
275 |
347 |
438 |
30 |
— |
— |
18 |
28 |
45 |
72 |
114 |
144 |
182 |
230 |
289 |
365 |
35 |
— |
— |
— |
24 |
39 |
62 |
98 |
124 |
156 |
197 |
248 |
313 |
40 |
— |
— |
— |
— |
34 |
54 |
86 |
108 |
136 |
172 |
217 |
274 |
45 |
— |
— |
— |
— |
30 |
48 |
76 |
96 |
121 |
153 |
193 |
243 |
50 |
— |
— |
— |
— |
27 |
43 |
69 |
87 |
109 |
138 |
174 |
219 |
Wire Sizing Chart 24 Volt System
Maximum one-way distance (feet) for 5% voltage loss in 24 volt systems. Wire Size (AWG)
Wire Sizing Chart 12 Volt System
Maximum one-way distance, in feet of two conductor copper wire for 5% voltage loss in 12 volt systems. Wire Size (AWG)
May double distance if 4% loss is ok.
Never exceed 2% drop for wire connecting PV modules and batteries.
Usually 4-5% loss ok for connecting batteries and lighting circuits.
Multiply distances by 2 for 24 volts and by 4 for 48 volts.
|